    The EDVC Automatic Recirculation Control (ARC )Valve is utilized as a  Pump Protections System.
    Features:                                                                                ZDM series automatic recirculatiocontrol valve
    1. Dependable Operation
    2. Modulating                                              
    3. Low maintenance
    4. Easy to install
    5. Dampens of system pulsations
    6. Suitable for all fluids
    7. Self powered











    Application of 
    Automatic Recirculation Control (ARC )Valve                                                                         Operation of Automatic Recirculation Control (ARC )Valve          Automatic recirculation valves protect centrifugal pumps against                                                     The main flow positions the check valve at a certain point. The stem of              overheating, excessive noise, instability and cavitation during low flow                                            Check valve transmits the motion via a lever to the bypass.
    conditions.                                                                                                                                          The bypass system controls the bypass flow in a modulating way and reduce                                                                                                                                                                  the pressure to bypass outlet level.   
    If the flow through the pump falls below a certain level the bypass                                                    The full minimum flow is bypassed when the check valve is seated. 
    system opens and the fluid will be recirculated providing the required                                               The bypass is fully closed when the check valve is in its upper position,
    minimum flow through the pump.                                                                                                         thereby allowing full pump flow to the system.


                                                                         Fig.1: Drawing of an Automatic Recirculation Valve type ZDM
    Drawing of ARC valve